Technical data
| Replace open pipe Ø (mm) |
8 |
| Blowing force (N) |
12.0 |
| Air consumption (Nm³/h) |
70 |
| Sound level (dB(A)) |
90 |
| Nozzle technology |
Laval |
| Material (nozzle) |
EPDM |
| Connection |
G 3/8″ |
| Connection type |
Female |
| Weight (kg) |
0.0270 |
| Max temp (°C) |
70 |
| Max op. pressure (MPa) |
1.0 |
Benefits when replacing an open pipe
| Replace open pipe Ø (mm) |
8 |
|
| Noise reduction |
18 [dB(A)] |
71% |
| Energy savings |
48 [Nm³/h] |
41% |
Material specification: EPDM 80, EN 1.4305
Blowing properties at different pressures
| Pressure (kPa) |
200 |
400 |
600 |
800 |
1000 |
| Blowing force (N) |
4.8 |
9.7 |
15.0 |
19.5 |
24.5 |
| Air consumption (Nm³/h) |
35.2 |
58.9 |
81.8 |
105.0 |
127.8 |
| Sound level (dB(A)) |
82.2 |
88.2 |
92.3 |
95.4 |
97.5 |
Blowing coverage
| Blowing dist. (mm) |
Blowing coverage (mm) |
| 50 |
82 |
| 100 |
108 |
| 200 |
162 |
| 300 |
215 |
| 400 |
268 |
| 500 |
321 |