Technical data
Replace open pipe Ø (mm) |
12 |
Blowing force (N) |
24.0 |
Air consumption (Nm³/h) |
128 |
Sound level (dB(A)) |
96 |
Nozzle technology |
Laval |
Material (nozzle) |
EPDM |
Connection |
G 1/2″ |
Connection type |
Female |
Weight (kg) |
0.0530 |
Max temp (°C) |
70 |
Max op. pressure (MPa) |
1.0 |
Benefits when replacing an open pipe
Replace open pipe Ø (mm) |
12 |
|
Noise reduction |
20 [dB(A)] |
75% |
Energy savings |
138 [Nm³/h] |
52% |
Material specification: EPDM 80, EN 1.4305
Blowing properties at different pressures
Pressure (kPa) |
200 |
400 |
600 |
800 |
1000 |
Blowing force (N) |
9.2 |
18.8 |
29.2 |
39.0 |
49.8 |
Air consumption (Nm³/h) |
57.4 |
102.5 |
154.0 |
204.0 |
255.0 |
Sound level (dB(A)) |
86.5 |
93.8 |
98.0 |
100.6 |
102.3 |
Blowing coverage
Blowing dist. (mm) |
Blowing coverage (mm) |
50 |
92 |
100 |
137 |
200 |
198 |
300 |
232 |
400 |
278 |
500 |
327 |